Breath-Triggered Drug Release for Preterm Neonates

Buch | Softcover
102 Seiten
2022
Shaker (Verlag)
978-3-8440-8870-0 (ISBN)

Lese- und Medienproben

Breath-Triggered Drug Release for Preterm Neonates - Felix Carl Wiegandt
39,80 inkl. MwSt
Inhalation therapy is a form of treatment for respiratory diseases. However, a major disadvantage of inhalation therapy with continuous drug delivery to the patient is the waste of drugs during exhalation. The development of a breath-triggered drug delivery system can greatly reduce this waste. Furthermore, in preterm and term neonates, this is further complicated by their challenging respiratory parameters such as high respiratory rate, low tidal volume, and short inhalation times. Given these challenges, there is currently no technology that enables breath-triggered drug release directly at the patient interface of preterm and term neonates. To close this gap, it is not only necessary to develop devices that enable efficient drug release at high frequencies, but also test beds that can be used to determine the efficiency of drug release. Moreover, the respiratory phases must be detected to release the aerosol in synchrony with the respiration.Therefore, an overall system consisting of aerosol output determination, breath-triggered aerosol release, and breath detection published by Wiegandt et al. is presented in this thesis as follows:1. A test bed, consisting of gravimetric and optical particle detection which allows the determination of the aerosol output in real time as well as the determination of the particles' water content.2. A breath-triggered aerosol delivery system consisting of a novel patient interface with an integrated micronized aerosol valve which allows direct and rapid breath-triggered delivery of aerosol as a targeted bolus at different times of inhalation.3. A respiratory detection system consisting of a time-of-flight camera for recording the abdominal movement of preterm neonates which enables the determination of respiratory parameters.

As of 2014, Felix has been working at Fraunhofer Institute for Toxicology and Experimental Medicine in Hannover, specializing in a breath-triggered drug delivery system for (pre)term infants. He developed a system that allows the release of an aerosol in a breath-triggered manner to (pre)term infants, achieving great improvements which far surpass the standard used in the clinic in terms of efficiency. With several publications and international patents under his belt, Felix knows the importance of driving innovation.

Erscheinungsdatum
Reihe/Serie Schriftenreihe Mikrotechnik
Verlagsort Düren
Sprache englisch
Maße 148 x 210 mm
Gewicht 149 g
Themenwelt Sachbuch/Ratgeber Natur / Technik Technik
Technik Medizintechnik
Schlagworte abdominal movement • Aerosol • breath-triggered drug release • Optical Detection • Preterm Infant • Preterm neonate • real-time measurement • test bed • time-of-flight camera
ISBN-10 3-8440-8870-9 / 3844088709
ISBN-13 978-3-8440-8870-0 / 9783844088700
Zustand Neuware
Haben Sie eine Frage zum Produkt?
Mehr entdecken
aus dem Bereich