Liquid Sample Introduction in ICP Spectrometry
A Practical Guide
Seiten
2008
Elsevier Science Ltd (Verlag)
978-0-444-53142-1 (ISBN)
Elsevier Science Ltd (Verlag)
978-0-444-53142-1 (ISBN)
- Titel ist leider vergriffen;
keine Neuauflage - Artikel merken
Inductively coupled plasma atomic or mass spectrometry is one of the most common techniques for elemental analysis. Because the sample introduction system can be a limiting factor in the analytical performance, it is crucial to optimize its design and its use. This book provides knowledge and instructions to obtain the best out of the technique.
Inductively coupled plasma atomic or mass spectrometry is one of the most common techniques for elemental analysis. Samples to be analyzed are usually in the form of solutions and need to be introduced into the plasma by means of a sample introduction system, so as to obtain a mist of very fine droplets. Because the sample introduction system can be a limiting factor in the analytical performance, it is crucial to optimize its design and its use. It is the purpose of this book to provide fundamental knowledge along with practical instructions to obtain the best out of the technique.
Inductively coupled plasma atomic or mass spectrometry is one of the most common techniques for elemental analysis. Samples to be analyzed are usually in the form of solutions and need to be introduced into the plasma by means of a sample introduction system, so as to obtain a mist of very fine droplets. Because the sample introduction system can be a limiting factor in the analytical performance, it is crucial to optimize its design and its use. It is the purpose of this book to provide fundamental knowledge along with practical instructions to obtain the best out of the technique.
By Jose-Luis Todoli, Department of Analytical Chemistry, Nutrition and Bromatology, University of Alicante, Spain; and Jean-Michel Mermet, Spectroscopy Forever, Tramoyes, France
1. History-Introduction2. Specifications of a sample introduction system to be used with an ICP3. Nebulizers. Pneumatic designs.4. Spray chambers5. Desolvation systems6. Matrix effects7. Selection and maintenance of sample introduction systems8. Applications
Erscheint lt. Verlag | 10.9.2008 |
---|---|
Verlagsort | Oxford |
Sprache | englisch |
Maße | 165 x 240 mm |
Gewicht | 560 g |
Themenwelt | Naturwissenschaften ► Chemie ► Analytische Chemie |
ISBN-10 | 0-444-53142-4 / 0444531424 |
ISBN-13 | 978-0-444-53142-1 / 9780444531421 |
Zustand | Neuware |
Haben Sie eine Frage zum Produkt? |
Mehr entdecken
aus dem Bereich
aus dem Bereich