The Lightning Rod as a Danger (eBook)

eBook Download: PDF
2023 | 1. Auflage
XXIX, 211 Seiten
Springer-Verlag
978-3-031-30434-7 (ISBN)

Lese- und Medienproben

The Lightning Rod as a Danger -  Jan Meppelink
Systemvoraussetzungen
117,69 inkl. MwSt
  • Download sofort lieferbar
  • Zahlungsarten anzeigen

This book investigates the physical effects of a lightning flash on a person near the down conductor of a lightning protection system. These effects are the touch voltage, the step voltage and the side flash. For this purpose, a full-scale simulation model of the human body with a resistance of 1000 ohms was first created. In the simulation model, the body can touch the down conductor or be placed close to it. Furthermore, the specific resistance of the earth is varied. Likewise, insulating layers such as asphalt can be incorporated into the simulation model. Also, special cases like water permeable layers or water layers on an asphalt layer can be calculated. In post-processing, all relevant values can be determined, such as the energy converted in the body, the charge, the current and the voltage applied to the body. A comparison with the permissible limit values then shows for the lightning protection classes whether there is danger or not and provides information on necessary measures. There is a risk for death and injury if the down conductor is touched. However, there is also a risk of a side flash if a person is standing next to a discharge. Site isolation with dry asphalt is effective, but there is a residual risk of surface discharges. In real situations with wet asphalt, water-permeable layers or asphalt with a water layer, however, there is a great risk of death or injury. Equipotential bonding with an earthing grid is a necessary but not sufficient solution with regard to the induced voltage at negative subsequent stroke. Therefore, the situation must always be examined on a case-by-case basis with regard to the safety requirements. The only effective measure to prevent injury and death due to touch voltage is an insulating down conductor in conjunction with equipotential bonding. The measures for reducing the touch voltage, such as site insulation and equipotential bonding, basically also apply to limiting the step voltage. A risk calculation according to IEC 62305-2 gives the mean time between two events of injury and death MG = 1/RA. The tolerable risk is: RA = 0,0001 or MT = 10.000 years, equivalent to one death in 10.000 years.



Jan Meppelink received his Dipl.-Ing. Degree and Dr.-Ing. in electrical engineering from the Technical University of Berlin. From 1984 to 1988, he was Leader of Basic Development High Voltage Engineering, ABB High Voltage Technologies, Zürich, Switzerland. He was Leader of the study group 'Principle Development' in High Voltage Engineering and Gas-Insulated Switchgear (GIS), especially for the performance verification testing of 800 kV Gas-Insulated Switchgear and commissioning of the 550 kV GIS Itaipu/Brazil, the development of the EMI proof design of secondary equipment for high voltage substations, research on propagation and measurement of very fast transients in GIS and development of ultra-fast voltage dividers for very fast transient measurements. From 1988 to 1992, he was Manager Projects International Gas-Insulated Switchgear, ABB High Voltage Technologies, Zürich, Switzerland. He was Leader of the Department for order handling and project management and also Leader of the Engineering Department. Since 1992, he is Professor for High Voltage Engineering at the University of applied Sciences, Soest, Germany. Since 2008, he is  Course Director of the Study Course 'Engineering and Project Management'. His field of research includes high voltage engineering, lightning and over voltage protection and along with the study course engineering and project management, lean management, process management, project management and sales engineering. Since 2015, he is Professor Emeritus. He is Head of the German working group AK 251-04 dealing with standardisation of lightning protection system components and Member of IEC TC81, MT8, MT14, MT21 and Cenelec TC81X WG2. 

 

In 2021, he received the Benjamin Franklin medal from the German VDE/ABB. In 2022, he received the IEC 1906 award from IEC.

Erscheint lt. Verlag 13.6.2023
Zusatzinfo XXIX, 211 p. 195 illus., 157 illus. in color.
Sprache englisch
Themenwelt Naturwissenschaften Biologie
Technik Elektrotechnik / Energietechnik
Schlagworte Insulating down conductor • Lightning flash • Protection measures to protect people • Risk of injury and death • Side flash • Step Voltage • Touch Voltage
ISBN-10 3-031-30434-9 / 3031304349
ISBN-13 978-3-031-30434-7 / 9783031304347
Haben Sie eine Frage zum Produkt?
PDFPDF (Wasserzeichen)
Größe: 12,6 MB

DRM: Digitales Wasserzeichen
Dieses eBook enthält ein digitales Wasser­zeichen und ist damit für Sie persona­lisiert. Bei einer missbräuch­lichen Weiter­gabe des eBooks an Dritte ist eine Rück­ver­folgung an die Quelle möglich.

Dateiformat: PDF (Portable Document Format)
Mit einem festen Seiten­layout eignet sich die PDF besonders für Fach­bücher mit Spalten, Tabellen und Abbild­ungen. Eine PDF kann auf fast allen Geräten ange­zeigt werden, ist aber für kleine Displays (Smart­phone, eReader) nur einge­schränkt geeignet.

Systemvoraussetzungen:
PC/Mac: Mit einem PC oder Mac können Sie dieses eBook lesen. Sie benötigen dafür einen PDF-Viewer - z.B. den Adobe Reader oder Adobe Digital Editions.
eReader: Dieses eBook kann mit (fast) allen eBook-Readern gelesen werden. Mit dem amazon-Kindle ist es aber nicht kompatibel.
Smartphone/Tablet: Egal ob Apple oder Android, dieses eBook können Sie lesen. Sie benötigen dafür einen PDF-Viewer - z.B. die kostenlose Adobe Digital Editions-App.

Buying eBooks from abroad
For tax law reasons we can sell eBooks just within Germany and Switzerland. Regrettably we cannot fulfill eBook-orders from other countries.

Mehr entdecken
aus dem Bereich