Basics of PET Imaging - Gopal B. Saha

Basics of PET Imaging

Physics, Chemistry, and Regulations

(Autor)

Buch | Softcover
241 Seiten
2014 | 2nd ed. 2010
Springer-Verlag New York Inc.
978-1-4899-8471-5 (ISBN)
90,94 inkl. MwSt
This reference on the basics of PET and PET/CT imaging has been revised with concise chapters on PET fundamentals. The chapters include pertinent basic science plus equations along with sample problems and practice questions.
Sincethepublicationofthisbook in2005, thegrowthofpositron emission tomography(PET)andPET/CTmodalityhasbeenphenomenalwiththed- coveryofef?cientdetectorsandtheadditionofsophisticatedscannersand powerfulsoftware. Becauseofthevastadvancementandchangesintechn- ogy, andalso withgreatappreciationofthesuccess ofthe?rst edition, we thoughtasecondeditionofthebookwouldbeappropriate. Thebookisrevisedtoagainful?lltheneedsofnuclearmedicineprof- sionalssuchasphysicians, technologists, andresidents, alongwithstudents fortheirboardexaminationandtraining. Thecontentsofthebookhavebeen keptatthebasiclevelaswasinthe?rstedition. The organization of the book essentially has remained the same. Some chaptershavebeenrevisedvery extensively, while others haveonly minor changes. NochangehasbeenmadeinChap. 1asitisbasedonbasicphysics. Extensive revision has been made in Chaps. 2 and 3 to include up-to-date information on detectors, scanners, and data collection. Chapter 4 in the original edition has been divided into Chaps. 4 and 5 to allow for a se- ratechapteron"Storage,Display,andPACS. "Chapter6hasbeenupdated withnewinformationonNEMAstandardsonacceptancetestsofPETsc- ners.
NewPETradionuclidesandthelistofcurrentavailablecyclotronshave beenaddedtoChap. 7. Chapter8includesasectiononCompoundingofPET Radiopharmaceuticals,inadditiontoseveralnewPETradiopharmaceuticals. NewregulationsconcerningtheuseofPETradiopharmaceuticals,thelice- ingofphysiciansandtechnologists,andtheaccreditationofPETfacilitiesto beeligibleforreimbursementforPETproceduresareallincludedinChap. 9. Chapter10hasbeenrevised,focusingontheissuesofcurrentreimbursement issuesforPETstudies. OnlyminorchangeshavebeenmadeinChaps. 11and 12toincludeup-to-dateinformation. Questionshavebeenaddedattheend ofeachchapter,asappropriate,tore?ectthechangesincontents. IthankmycolleaguesattheClevelandClinicFoundationfortheirsupport in manywaysand Mrs. DianeGrif?s for kindly typingand completingthe manuscriptontime. vii viii Preface IsincerelythankAndrewMoyer,editorofradiologyandnuclearmedicine, atSpringerforsupportandencouragement,andS. GeethalakshmiSrinivasan, ProjectManager,atSPiTechnologiesIndiaPvtLtdforexcellentproduction ofthebook. Cleveland,OH GopalB. Saha Contents 1. RadioactiveDecayandInteractionofRadiationwithMatter ...1 AtomicStructure ...1 RadioactiveDecay ...2 ?Decay ...2 ? ? Decay ...3 + Positron(?)
Decay ...3 ElectronCapture ...3 IsomericTransition ...4 RadioactiveDecayEquations ...5 GeneralDecayEquations ...5 SuccessiveDecayEquations ...7 UnitsofRadioactivity ...9 UnitsofRadioactivityinSystemInternationale ...9 Calculations ...9 InteractionofRadiationwithMatter ...10 InteractionofChargedParticleswithMatter ...10 Interactionof?RadiationwithMatter ...12 Questions ...15 ReferencesandSuggestedReading ...17 2. PET ScanningSystems ...19 Background ...19 SolidScintillationDetectorsinPET ...20 PhotomultiplierTube ...24 PulseHeightAnalyzer ...25 ArrangementofDetectors ...25 PETScanners ...28 CoincidenceScintillationCameras ...29 PET/CTScanners ...30 SmallAnimalPETScanner ...33 MobilePETorPET/CT ...36 ix x Contents Questions ...38 ReferencesandSuggestedReading ...39 3. DataAcquisition and Corrections ...41 PETDataAcquisition ...41 TimeofFlightMethod ...46 Two-Dimensionalvs. Three-Dimensional DataAcquisition ...47 FactorsAffectingAcquiredPETData ...49 Normalization ...49 PhotonAttenuation ...50 AttenuationCorrectionMethods ...52 RandomCoincidences ...53 ScatterCoincidences ...55 CorrectionforScatterCoincidences ...56 DeadTime ...58 RadialElongation ...59 PET/CTDataAcquisition ...6
0 FactorsAffectingPET/CTData ...62 Questions ...67 ReferencesandSuggestedReading ...68 4. ImageReconstruction ...71 SimpleBackprojection ...71 FilteredBackprojection ...72 TheFourierMethod ...73 TypesofFilters ...75 IterativeReconstruction ...

Radioactive Decay and Interaction of Radiation with Matter.- PET Scanning Systems.- Data Acquisition and Corrections.- Image Reconstruction.- Storage, Display, and PACS.- Performance Characteristics of PET Scanners.- Cyclotron and Production of PET Radionuclides.- Synthesis of PET Radiopharmaceuticals.- Regulations Governing PET Radiopharmaceuticals.- Reimbursement for PET Procedures.- Design and Cost of PET Center.- Procedures for PET Studies.

Erscheint lt. Verlag 26.11.2014
Zusatzinfo XIV, 241 p.
Verlagsort New York
Sprache englisch
Maße 155 x 235 mm
Themenwelt Medizinische Fachgebiete Radiologie / Bildgebende Verfahren Nuklearmedizin
Medizinische Fachgebiete Radiologie / Bildgebende Verfahren Radiologie
Medizin / Pharmazie Studium 1. Studienabschnitt (Vorklinik)
Naturwissenschaften Biologie Biochemie
ISBN-10 1-4899-8471-2 / 1489984712
ISBN-13 978-1-4899-8471-5 / 9781489984715
Zustand Neuware
Informationen gemäß Produktsicherheitsverordnung (GPSR)
Haben Sie eine Frage zum Produkt?
Mehr entdecken
aus dem Bereich
Basiswissen und klinische Anwendung

von Markus Dietlein; Klaus Kopka; Matthias Schmidt …

Buch (2023)
Thieme (Verlag)
145,00