This book systemically introduces physical properties and clinical application of total body PET/CT. Firstly, based on the results of a comparative study between total body PET/CT and conventional digital PET/CT, the feasibility and diagnostic efficacy of rapid scanning are overviewed. Following chapters present the unique value of total body PET/CT dynamic acquisition in pharmacokinetic research and its potential advantages, feasibility and optimized imaging of half-dose and one-tenth-dose total body PET/CT scans. In addition, new technologies that are still being explored and perfected, such as gating technology and ultra-low dose CT are also included. It will be a useful reference for nuclear medicine physician and radiologist who are interested in total body PET/CT.

Hongcheng Shi is a Professor and Director at the Department of Nuclear Medicine, Zhongshan Hospital, Fudan University, Shanghai, China. Guobing Liu and Hui Tan are Attending Physicians at the same Department with Professor Hongcheng Shi. Yiqiu Zhang and Pengcheng Hu are Associate Chief Physicians at the same Department with Professor Hongcheng Shi

Development, characteristics and clinical application of total body PET/CT.- Comparison of total body PET/CT and conventional PET/CT.- Clinical application of total-body PET/CT fast scan.- Application of total body PET/CT in evaluation of radiotracer biodistribution in human.- Interpretation and application of total-body PET/CT dynamic acquisition information.- Clinical application of low dose total body PET/CT scan.- Clinical application of extra low dose total body PET/CT scan.- Exploration of application technology in total body PET/CT.- Interpretation of the consensus of oncological 18F-FDG total-body PET/CT imaging.- Recommended workflow of total body PET/CT application in clinical.

Erscheint lt. Verlag 2.12.2024
Zusatzinfo Approx. 140 p. 60 illus., 50 illus. in color.
Verlagsort Singapore
Sprache englisch
Maße 178 x 254 mm
Themenwelt Medizinische Fachgebiete Radiologie / Bildgebende Verfahren Nuklearmedizin
Schlagworte extra low dose total body PET/CT • low dose total body PET/CT • PET/CT • Radiotracer biodistribution • Total-Body PET/CT
ISBN-10 981-97-5064-4 / 9819750644
ISBN-13 978-981-97-5064-1 / 9789819750641
Zustand Neuware
Haben Sie eine Frage zum Produkt?
Mehr entdecken
aus dem Bereich
Basiswissen und klinische Anwendung

von Markus Dietlein; Klaus Kopka; Matthias Schmidt …

Buch (2023)
Thieme (Verlag)
145,00