RadCases Plus Q&A Nuclear Medicine - Daniel E. Appelbaum, John Miliziano, Anup J. Alexander, Yong Bradley

RadCases Plus Q&A Nuclear Medicine (eBook)

eBook Download: EPUB
2020 | 2. Auflage
260 Seiten
Thieme Medical Publishers (Verlag)
978-1-63853-305-4 (ISBN)
Systemvoraussetzungen
64,99 inkl. MwSt
  • Download sofort lieferbar
  • Zahlungsarten anzeigen

Essential nuclear medicine cases and board-type Q&A review to help you pass your exam!

Recently, the field of nuclear medicine has witnessed an unprecedented explosion of new clinical diagnostic tracers, radionuclide therapies, hardware, and molecular imaging paradigms. This second edition of RadCases Plus Q&A Nuclear Medicine by Daniel Appelbaum, John Miliziano, Anup Jacob Alexander, and Yong Bradley reflects these advances, presenting 100 new cases and 500 high-quality images. The book covers a wide spectrum, from classic topics, such as thyroid, bone, parathyroid, and renal scans, to the paradigm-shifting concept of 'theranostics.' For maximum ease of self-assessment, each case begins with the clinical presentation on the right-hand page; study that and then turn the page for imaging findings, differential diagnoses with the definitive diagnosis, essential facts, pearls and pitfalls, and more.

Key Highlights

  • The latest radionuclide therapies to treat cancers of the prostate, neuroendocrine system, and liver
  • Discussion of up-to-date diagnostic and therapeutic PET radiotracers, theraspheres/sirspheres, and new cardiac applications for PYP SPECT
  • Recently described important artifacts such as WBC and FDG microemboli, white fat hypermetabolism, and the potentially confusing inflammation patterns in FDG PET associated with emerging cancer immunotherapies
  • Timeless topics include radiation handling/safety and resolving camera imaging errors

 

Thieme's RadCases means cases selected to simulate what you will see on your exams, rounds, and rotations. RadCases helps you to identify the correct differential diagnosis for each case, including the most critical. The series comprehensively covers the following specialties:

  • Breast Imaging · Cardiac Imaging · Emergency Imaging · Gastrointestinal Imaging · Genitourinary Imaging · Head and Neck Imaging · Interventional Radiology · Musculoskeletal Radiology · Neuro Imaging · Nuclear Medicine · Pediatric Imaging · Thoracic Imaging · Ultrasound Imaging

 

This RadCases book comes with a code providing access to additional online cases: 100 in this book plus 250+ more cases and interactive Q&A

Master your cases, pass your exams, and diagnose with confidence: RadCases!

This print book includes complimentary access to a digital copy on https://medone.thieme.com.

Publisher's Note: Products purchased from Third Party sellers are not guaranteed by the publisher for quality, authenticity, or access to any online entitlements included with the product.

Case Questions and Answers

The questions and answers in the following section are numbered as cases 1 through 100. The questions correspond to the respectively numbered case reviews and are intended to be answered after working through the cases.

Case 1

1.The most reliable sign of a “metastatic superscan” on bone scintigraphy is:

a)Decreased soft tissue and renal activity

b)An abrupt decrease of osseous activity beyond the proximal extremities

c)Diffusely increased activity of the entire (axial and appendicular) skeleton

d)No focal osseous lesion

The correct answer is (b). Abrupt decrease of osseous activity beyond the proximal extremities is due to the fact that typical skeletal metastases localize to the hematopoietic (red) marrow, which is located centrally in adults.

2.Which of the following would be least likely to cause diffusely increased uptake in the entire axial and appendicular skeleton?

a)A 60-year-old man with prostate cancer

b)A 2-year-old girl with metastatic neuroblastoma

c)A 50-year-old woman with hyperparathyroidism

d)A 40-year-old man with chronic kidney disease

The correct answer is (a). Increased uptake throughout the entire axial and appendicular skeleton describes a “metabolic superscan,” which can be seen in patients with metabolic bone disease such as hyperparathyroidism or in pediatric patients in which red marrow remains diffuse. A 60-year-old man with prostate cancer would display a “metastatic superscan” in which there would be decreased osseous activity beyond the proximal appendicular skeleton.

Case 2

1.All of the following are treatment options for Graves’ disease except:

a)Methimazole

b)Surgical resection

c)Iodinated contrast

d)Radioiodine ablation

The correct answer is (c). Iodinated contrast can inhibit radioiodine uptake and thereby interfere with a thyroid uptake and scan and at one time was used to treat hyperthyroidism due to Wolff–Chaikoff effect, which can transiently suppress organification of iodine. However, it is not considered a modern treatment option, unlike the other choices.

2.True or false: Diffusely (no nodules) elevated thyroid radioiodine uptake on thyroid uptake and scan is pathognomonic for Graves’ disease.

a)True

b)False

The correct answer is (b). Although it is most commonly Graves disease, there are other possibilities. Diffuse, elevated thyroid radioiodine uptake can also be seen in some hypothyroid patients and in iodine-deficient patients with increased dose of iodine from iodinate contrast (e.g., Jod–Basedow phenomenon). And although rare, pituitary tumors can secrete increased amounts of TSH, causing diffusely increased uptake and hyperthyroidism.

Case 3

1.What is the maximum allowed effective dose equivalent to an individual member of the general public?

a)5.0 rem

b)0.1 rem

c)0.5 rem

d)50 rem

The correct answer is (b). Annual radiation dose limit for members of the public may not exceed 0.1 rem/year (1 mSv/year) total effective dose equivalent (TEDE).

2.What is the annual exposure dose limit to a radiation worker?

a)5.0 rem

b)0.1 rem

c)0.5 rem

d)50 rem

The correct answer is (a). Annual occupational dose limit for an adult radiation worker is 5.0 rem (50 mSv) total effective dose equivalent (TEDE).

3.What is the exposure dose limit to the extremity of a radiation worker?

a)5.0 rem

b)0.1 rem

c)0.5 rem

d)50 rem

The correct answer is (d). Organ-specific annual exposure limits are:

50 rem (500 mSv) to the extremities. Shallow dose equivalent.

50 rem (500 mSv) to any organ except the lens of the eye. Deep dose equivalent (DDE) 1 committed dose equivalent (CDE).

15 rem (150 mSv) to the lens of the eye. Lens dose equivalent.

Case 4

1.Which of the following dementias would be most likely to involve the lateral occipital cortices with preservation of the posterior cingulate gyri on FDG-PET?

a)Alzheimer’s dementia

b)Multi-infarct dementia

c)Lewy body dementia

d)Frontotemporal dementia

The correct answer is (c). Preservation of the posterior cingulate gyrus can be present in Lewy body dementia (cingulate island sign), whereas it is commonly involved in Alzheimer’s dementia. Alzheimer’s dementia and frontotemporal dementia spare the occipital cortex, whereas Lewy body dementia involves the occipital cortex.

2.Which of the following conditions can mimic multiinfarct dementia findings on FDG-PET?

a)Alzheimer’s dementia

b)AIDS-associated dementia

c)Lewy body dementia

d)Tc99m MIBI The correct answer is (b). Note that with an increased prevalence of PET scanners, FDG is better than Tl-201 in identifying hibernating myocardium, if done with proper protocol (i.e., administering glucose and insulin).

Case 5

1.On gated rest-stress myocardial perfusion scintigraphy, hibernating myocardium may have the appearance of:

a)Reversible ischemia

b)Stunned myocardium

c)Infarcted myocardium

d)Attenuation artifact

The correct answer is (c). Without the benefit of additional imaging, such as F-18 FDG images or delayed Tl-201 images, infarcted and hibernating myocardium both have perfusion abnormalities on both stress and rest imaging with associated hypokinesis. Additional imaging will reveal metabolic activity or delayed reversibility confirming hibernating myocardium. Stunned myocardium, usually found immediately after angioplasty in a patient with ongoing MI, typically has normal or near-normal perfusion with hypokinesis, which later demonstrates improved motion if the angioplasty was performed early enough.

2.Viable hibernating myocardium is best detected with which of the following tracers?

a)Tc99m tetrofosmin

b)Rubidium-82

c)Thallium-201

d)Attenuation artifact Tc99m MIBI

The correct answer is (c). Thallium-201 is a potassium channel analogue and redistributes to intact cell membranes (hibernating cells), distinguishing this from infarcted tissue (scar). Perfusion PET with rubidium-82 will show resting defects for both infarcted and hibernating tissue, as 82Rb is a flow agent. Tc99m MIBI and tetrofosmin are mitochondrial binding agents and do not redistribute. With increased prevalence of PET scanners, F-18 FDG is the best modality to identify hibernating myocardium because it will reveal discordant findings when compared with flow agents, if done with proper protocol (i.e., using glucose and insulin).

Case 6

1.Which of the following conditions and findings pairs on FDG-PET are correct?

a)Nonfasting altered biodistribution; diffusely increased muscle uptake

b)Brown fat hypermetabolism; diffusely increased muscle uptake

c)Brown fat hypermetabolism; focal skeletal muscle uptake

d)Nonfasting altered biodistribution; focal skeletal muscle uptake

The correct answer is (a). A nonfasting state leads to elevated insulin levels, which drives both glucose and FDG into normal cells, especially muscle, decreasing the available FDG for the tumor cells. This also makes tumor cells less apparent given the lower ratio of tumor to normal tissue.

2.Where is brown fat hypermetabolism least likely to be encountered?

a)Neck

b)Chest

c)Abdomen

d)Pelvis

The correct answer is (d). BAT hypermetabolism is most frequently observed symmetrically in the neck, supraclavicular spaces, paraspinal (thoracic) locations, and often mediastinal locations. Occasionally, BAT uptake is observed below the diaphragm within the upper abdomen (typically perirenal). BAT activity more inferiorly within the pelvis is rare.

3.Which of the following scenarios would result in increased regional skeletal muscle uptake?

a)Hyperinsulinemia (e.g., nonfasting state)

b)Recent exercise

c)Brown fat hypermetabolism

d)Hyperglycemia

The correct answer is (b). Regional skeletal muscle uptake is most commonly seen after recent exercise (a form of myositis). Hyperinsulinemia and hyperglycemia can lead to diffuse skeletal muscle uptake. Brown fat hypermetabolism would be observed symmetrically in the fat located in the neck, supraclavicular spaces, paraspinal (thoracic) locations, and often mediastinal locations, which are readily localized on a PET/CT scan.

Case 7

1.On a HIDA scan, which of the following may...

Erscheint lt. Verlag 28.10.2020
Reihe/Serie Radcases Plus Q&A
Zusatzinfo Beilage: Online resource
Verlagsort Stuttgart
Sprache englisch
Themenwelt Medizinische Fachgebiete Radiologie / Bildgebende Verfahren Radiologie
Schlagworte Molecular Imaging • PET • radiologic diagnosis • radiology board reveiw • Radiology Cases • Radionuclide imaging • SPECT
ISBN-10 1-63853-305-9 / 1638533059
ISBN-13 978-1-63853-305-4 / 9781638533054
Haben Sie eine Frage zum Produkt?
EPUBEPUB (Wasserzeichen)
Größe: 19,5 MB

DRM: Digitales Wasserzeichen
Dieses eBook enthält ein digitales Wasser­zeichen und ist damit für Sie persona­lisiert. Bei einer missbräuch­lichen Weiter­gabe des eBooks an Dritte ist eine Rück­ver­folgung an die Quelle möglich.

Dateiformat: EPUB (Electronic Publication)
EPUB ist ein offener Standard für eBooks und eignet sich besonders zur Darstellung von Belle­tristik und Sach­büchern. Der Fließ­text wird dynamisch an die Display- und Schrift­größe ange­passt. Auch für mobile Lese­geräte ist EPUB daher gut geeignet.

Systemvoraussetzungen:
PC/Mac: Mit einem PC oder Mac können Sie dieses eBook lesen. Sie benötigen dafür die kostenlose Software Adobe Digital Editions.
eReader: Dieses eBook kann mit (fast) allen eBook-Readern gelesen werden. Mit dem amazon-Kindle ist es aber nicht kompatibel.
Smartphone/Tablet: Egal ob Apple oder Android, dieses eBook können Sie lesen. Sie benötigen dafür eine kostenlose App.
Geräteliste und zusätzliche Hinweise

Buying eBooks from abroad
For tax law reasons we can sell eBooks just within Germany and Switzerland. Regrettably we cannot fulfill eBook-orders from other countries.

Mehr entdecken
aus dem Bereich

von Marija Pinto

eBook Download (2023)
Urban & Fischer Verlag - Lehrbücher
26,99