Collimator-Based Tracking with an Add-On Multileaf Collimator

Modification of a commercial collimator system for realtime applications

(Autor)

Buch | Softcover
XIV, 53 Seiten
2015 | 1st ed. 2016
Springer Fachmedien Wiesbaden GmbH (Verlag)
978-3-658-10657-7 (ISBN)
64,19 inkl. MwSt

In this thesis, a tracking system was developed by modifying an add-on collimator, the Siemens Moduleaf, for realtime applications in radiotherapy. As the add-on collimator works almost completely autonomously of the linear accelerator (LinAc), no modifications to the latter were necessary. The adaptations to the Moduleaf were mainly software-based. In order to reduce the complexity of the system, outdated electronic parts were replaced with newer components where practical.

Verification was performed by measuring the latency of the system as well as the impact on applied dose to a predefined target volume, moving in the leaf's travel direction. Latency measurements in software were accomplished by comparing the target and current positions of the leaves. For dose measurements, a Gafchromic EBT2 film was placed beneath the target 4D phantom, in between solid water plates, and moved alongside with it.

Based on the results, a tracking-capable add-on collimator seems to be a useful tool for reducing the margins for the treatment of small, slow-moving targets.

Radiotherapy is one of the most important methods used for the treatment of cancer. Irradiating a moving target is also one of the most challenging tasks to accomplish in modern radiotherapy.

After his graduation in 2014, Andreas Böhler co-founded the R'n'B Medical Software Consulting GmbH headquartered in Linz/Austria. The company focuses on quality management consulting and also offers a fully electronic quality management system. Given the strong medical and technical backgrounds of the founders, they are also specialised in clinical evaluations.

1 Introduction.- 2 Literature Overview.- 3 Hypothesis & Goals.- 4 Materials & Methods.- 5 Results.- 6 Discussion.- 7 Conclusions.

Erscheint lt. Verlag 9.10.2015
Reihe/Serie BestMedDiss
Zusatzinfo XIV, 53 p. 18 illus., 14 illus. in color.
Verlagsort Wiesbaden
Sprache englisch
Maße 148 x 210 mm
Themenwelt Medizin / Pharmazie Medizinische Fachgebiete Onkologie
Medizin / Pharmazie Medizinische Fachgebiete Radiologie / Bildgebende Verfahren
Schlagworte 4D Phantom and Measurements • Multileaf Collimator • Radiaton Oncology • radiotherapy • Software Adaptations and Software Implementation • Tracking
ISBN-10 3-658-10657-3 / 3658106573
ISBN-13 978-3-658-10657-7 / 9783658106577
Zustand Neuware
Haben Sie eine Frage zum Produkt?
Mehr entdecken
aus dem Bereich

von Hannes Leischner

Buch | Softcover (2023)
Urban & Fischer in Elsevier (Verlag)
27,00
Resilienz innovativ stärken : ein Praxishandbuch

von Christa Diegelmann; Margarete Isermann; Tanja Zimmermann

Buch | Softcover (2023)
Kohlhammer (Verlag)
36,00