The Dynamic Hip Screw Implant System - P. Regazzoni, T. Rüedi, R. Winquist, M. Allgöwer

The Dynamic Hip Screw Implant System

Buch | Softcover
V, 51 Seiten
2011 | 1. Softcover reprint of the original 1st ed. 1985
Springer Berlin (Verlag)
978-3-642-69927-6 (ISBN)
53,49 inkl. MwSt
The AOjASIF* dynamic hip screw (DRS) has been designed primarily to stabilize trochanteric fractures of the hip. Selected fractures of the femoral neck and some subtrochanteric fractures are further indications for the DRS [40, 46]. The dynam ic condylar screw (DCS) has been developed for fractures of the distal femur and is now being tested clinically. The DRS and DCS are carefully coordinated with the preexisting ASIF standard sets of equipment for internal fixation of fractures. The concept of a sliding screw for trochanteric fractures is not new. The first author describing such an implant was Schumpelick [44]; he gives credit to Pohl [22], who was primarily a manufacturer working for Gerhardt Kiinscher. Re described the possibility of impaction at the fracture site with a sliding device. In the United States Clawson [7, 8] introduced the hip screw and found it to be extremely beneficial in trochanteric fractures. At approximately the same time, Massie [31, 32] and Pugh [39] designed the sliding-type flange nails, which offer similar intramedullary splinting with the possibility of fracture impaction. The following chapters describe the concept and design features of the DRS, as well as the details of the surgical technique. The application of the DRS for different types of fractures is illustrated with clinical examples. The results of 268 cases of trochanteric fractures treated with the DRS are presented and compared with results using the angled blade plate and Ender's nails. Finally, some laboratory tests are described.

1 Introduction.- 2 The Problem of Trochanteric Fractures.- Classification.- Problems in Fixation.- 3 DHS Implant System.- Design Features.- Standard Surgical Technique.- Particular Technical Problems.- 4 Application of the DHS: Clinical Examples.- 5 Clinical Results: A Comparison.- Dynamic Hip Screw.- Angled Blade Plates.- Ender's Nails.- 6 Laboratory Tests with the DHS.- Methods and Materials.- Results and Discussion.- Conclusions.- 7 Summary.- 8 References.- 9 Subject Index.

Erscheint lt. Verlag 19.11.2011
Zusatzinfo V, 51 p. 32 illus.
Verlagsort Berlin
Sprache englisch
Maße 210 x 279 mm
Gewicht 181 g
Themenwelt Medizinische Fachgebiete Chirurgie Unfallchirurgie / Orthopädie
Medizin / Pharmazie Medizinische Fachgebiete Notfallmedizin
Schlagworte Fixation • Fracture • Hip • Implant • System • trauma surgery
ISBN-10 3-642-69927-8 / 3642699278
ISBN-13 978-3-642-69927-6 / 9783642699276
Zustand Neuware
Haben Sie eine Frage zum Produkt?
Mehr entdecken
aus dem Bereich
für Studium und Praxis unter Berücksichtigung des …

von Markus Müller; Achim Elsen; Matthias Eppinger

Buch | Softcover (2022)
Medizinische Vlgs- u. Inform.-Dienste (Verlag)
28,00