Understanding transient phenomena in electric power systems and the harmful impact of resulting disturbances is an important aspect of power system operation and resilience. Bridging the gap from theory to practice, this guide introduces the fundamentals of transient phenomena affecting electric power systems using the numerical analysis tools, Alternative Transients Program- Electromagnetic Transients Program (ATP-EMTP) and ATP-DRAW. This technology is widely-applied to recognize and solve transient problems in power networks and components giving readers a highly practical and relevant perspective and the skills to analyse new transient phenomena encountered in the field.
Key features:
- Introduces novice engineers to transient phenomena using commonplace tools and models as well as background theory to link theory to practice.
- Develops analysis skills using the ATP-EMTP program, which is widely used in the electric power industry.
- Comprehensive coverage of recent developments such as HVDC power electronics with several case studies and their practical results.
- Provides extensive practical examples with over 150 data files for analysing transient phenomena and real life practical examples via a companion website.
Written by experts with deep experience in research, teaching and industry, this text defines transient phenomena in an electric power system and introduces a professional transient analysis tool with real examples to novice engineers in the electric power system industry. It also offers instruction for graduates studying all aspects of power systems.
Eiichi Haginomori, University of Tokyo, Japan
Eiichi Haginomori is currently at the University of Tokyo. Previous to this he was in the Department of Electrical Engineering at Kyushu Institute of Technology (1998-2003) and in Chemical Engineering at Chuo University. At both universities he researched into EMTP application to Electrical Engineering. He was Chief Specialist in the Switchgear Engineering Department of Toshiba's Head Office for ten years, and belongs to IEC standard committee groups such as WG1 and WG10, in IEC SC17A (High-voltage Switchgear and controlgear).
Tadashi Koshiduka, Toshiba Co., Japan
Tadashi Koshizuka is currently a Senior Scientist at the High Power Technology Group in the Power & Industrial Systems Research & Development Center at Toshiba, Japan. Prior to this he worked as an engineer with the group (1998-2000), then a specialist (2000-2010). He is a technical paper reviewer in the Power and Energy Society of IEE Japan and current member and secretary of IEEDJ (The Institute of Engineers on Electrical Discharges in Japan). Mr Koshizuka holds three Japanese Patents, has contributed to 17 papers and co-authored one book.
Professor Arai is Chair of the Department of Electrical Engineering and Dean of the Faculty of Engineering at Kogakuin University. Previous to this he was Senior Fellow of the Transmission & Distribution System Division at Toshiba Corp., and Deputy Senior Chief Engineer in the International Marketing Division of TM T&D Corp. He has written seventeen papers related to the topic, a chapter in Electrical Engineering Handbook, published by IEE of Japan, and a chapter in Liberalization of Electricity Markets and Technological Issues. He holds 10 patents related to his research in power control and circuits.
Hisatoshi Ikeda, University of Tokyo, Japan
Hisatoshi Ikeda is currently Project Professor, having been Visiting Professor at Kyushu Institute of Technology for three years previously. From 2002 to 2007 he was General Manager, Transmission and Distribution Research and Development Center at TM T&D Co, andAssistant General Manager at Hamakawasaki-works, Toshiba Corp. Professor Ikeda holds 56 Japanese patents and 12 USA patents. He has been a secretary of the short-circuit testing liaison in Japan.
Understanding transient phenomena in electric power systems and the harmful impact of resulting disturbances is an important aspect of power system operation and resilience. Bridging the gap from theory to practice, this guide introduces the fundamentals of transient phenomena affecting electric power systems using the numerical analysis tools, Alternative Transients Program- Electromagnetic Transients Program (ATP-EMTP) and ATP-DRAW. This technology is widely-applied to recognize and solve transient problems in power networks and components giving readers a highly practical and relevant perspective and the skills to analyse new transient phenomena encountered in the field. Key features: Introduces novice engineers to transient phenomena using commonplace tools and models as well as background theory to link theory to practice. Develops analysis skills using the ATP-EMTP program, which is widely used in the electric power industry. Comprehensive coverage of recent developments such as HVDC power electronics with several case studies and their practical results. Provides extensive practical examples with over 150 data files for analysing transient phenomena and real life practical examples via a companion website. Written by experts with deep experience in research, teaching and industry, this text defines transient phenomena in an electric power system and introduces a professional transient analysis tool with real examples to novice engineers in the electric power system industry. It also offers instruction for graduates studying all aspects of power systems.
Eiichi Haginomori, University of Tokyo, Japan Eiichi Haginomori is currently at the University of Tokyo. Previous to this he was in the Department of Electrical Engineering at Kyushu Institute of Technology (1998-2003) and in Chemical Engineering at Chuo University. At both universities he researched into EMTP application to Electrical Engineering. He was Chief Specialist in the Switchgear Engineering Department of Toshiba's Head Office for ten years, and belongs to IEC standard committee groups such as WG1 and WG10, in IEC SC17A (High-voltage Switchgear and controlgear). Tadashi Koshiduka, Toshiba Co., Japan Tadashi Koshizuka is currently a Senior Scientist at the High Power Technology Group in the Power & Industrial Systems Research & Development Center at Toshiba, Japan. Prior to this he worked as an engineer with the group (1998-2000), then a specialist (2000-2010). He is a technical paper reviewer in the Power and Energy Society of IEE Japan and current member and secretary of IEEDJ (The Institute of Engineers on Electrical Discharges in Japan). Mr Koshizuka holds three Japanese Patents, has contributed to 17 papers and co-authored one book. Junichi Arai, Kougakuin University, Japan Professor Arai is Chair of the Department of Electrical Engineering and Dean of the Faculty of Engineering at Kogakuin University. Previous to this he was Senior Fellow of the Transmission & Distribution System Division at Toshiba Corp., and Deputy Senior Chief Engineer in the International Marketing Division of TM T&D Corp. He has written seventeen papers related to the topic, a chapter in Electrical Engineering Handbook, published by IEE of Japan, and a chapter in Liberalization of Electricity Markets and Technological Issues. He holds 10 patents related to his research in power control and circuits. Hisatoshi Ikeda, University of Tokyo, Japan Hisatoshi Ikeda is currently Project Professor, having been Visiting Professor at Kyushu Institute of Technology for three years previously. From 2002 to 2007 he was General Manager, Transmission and Distribution Research and Development Center at TM T&D Co, andAssistant General Manager at Hamakawasaki-works, Toshiba Corp. Professor Ikeda holds 56 Japanese patents and 12 USA patents. He has been a secretary of the short-circuit testing liaison in Japan.
Preface ix
Part I Standard Course-Fundamentals and Typical Phenomena 1
1 Fundamentals of EMTP 3
1.1 Function and Composition of EMTP 3
1.1.1 Lumped Parameter RLC 3
1.1.2 Transmission Line 4
1.1.3 Transformer 6
1.1.4 Nonlinear Element 6
1.1.5 Arrester 6
1.1.6 Switch 7
1.1.7 Voltage and Current Sources 7
1.1.8 Generator and Rotating Machine 7
1.1.9 Control 7
1.1.10 Support Routines 7
1.2 Features of the Calculation Method 8
1.2.1 Formulation of the Main Circuit 8
1.2.2 Calculation in TACS 12
1.2.3 Features of EMTP 13
References 16
2 Modeling of System Components 17
2.1 Overhead Transmission Lines and Underground Cables 17
2.1.1 Overhead Transmission Line--Line Constants 17
2.1.2 Underground Cables--Cable Parameters 37
2.2 Transformer 46
2.2.1 Single-Phase Two-Winding Transformer 46
2.2.2 Single-Phase Three-Winding Transformer 50
2.2.3 Three-Phase One-Core Transformer--Three Legs or Five Legs 53
2.2.4 Frequency and Transformer Modeling 55
3 Transient Currents in Power Systems 57
3.1 Short-Circuit Currents 57
3.2 Transformer Inrush Magnetizing Current 60
3.3 Transient Inrush Currents in Capacitive Circuits 62
Appendix 3.A: Example of ATPDraw Sheets--Data3-02.acp 64
Reference 64
4 Transient at Current Breaking 65
4.1 Short-Circuit Current Breakings 66
4.2 Capacitive Current Switching 71
4.2.1 Switching of Capacitive Current of a No-Load Overhead Transmission Line 72
4.2.2 Switching of Capacitive Current of a Cable 75
4.2.3 Switching of Capacitive Current of a Shunt Capacitor Bank 76
4.3 Inductive Current Switching 78
4.3.1 Current Chopping Phenomenon 78
4.3.2 Reignition 79
4.3.3 High-Frequency Extinction and Multiple Reignition 80
4.4 TRV with Parallel Capacitance in SLF Breaking 80
Appendix 4.A: Current Injection to Various Circuit Elements 84
Appendix 4.B: TRV Calculation, Including ITRV--Current Injection is Applied for TRV Calculation 91
Appendix 4.C: 550 kV Line Normal Breaking 97
Appendix 4.D: 300 kV, 150 MVA Shunt Reactor Current Breaking--Current
Chopping--Reignition--HF Current Interruption 100
References 103
5 Black Box Arc Modeling 105
5.1 Mayr Arc Model 106
5.1.1 Analysis of Phenomenon of Short-Line Fault Breaking 106
5.1.2 Analysis of Phenomenon of Shunt Reactor Switching 110
5.2 Cassie Arc Model 112
5.2.1 Analysis of Phenomenon of Current Zero Skipping 113
Appendix 5.A: Mayr Arc Model Calculating SLF Breaking, 300 kV, 50 kA, L90 Condition 118
Appendix 5.B: Zero Skipping Current Breaking Near Generator--Fault Current Lasting 124
Appendix 5.C: Zero Skipping Current Breaking Near Generator--Dynamic Arc Introduced, Still Nonbreaking 131
6 Typical Power Electronics Circuits in Power Systems 135
6.1 General 135
6.2 HVDC Converter/Inverter Circuits 135
6.3 Static Var Compensator/Thyristor-Controlled Inductor 140
6.4 PWM Self-Communicated Type Inverter Applying the Triangular Carrier Wave Shape Principle--Applied to SVG (Static Var Generator) 142
Appendix 6.A: Example of ATPDraw Picture 147
Reference 148
Part II Advanced Course-Special Phenomena and Various Applications 149
7 Special Switching 151
7.1 Transformer-Limited Short-Circuit Current Breaking 151
7.2 Transformer Winding Response to Very Fast Transient Voltage 152
7.3 Transformer Magnetizing Current under Geomagnetic Storm Conditions 156
7.4 Four-Armed Shunt Reactor for Suppressing Secondary Arc in Single-Pole Rapid Reclosing 159
7.5 Switching Four-Armed Shunt Reactor Compensated Transmission Line 162
References 163
8 Synchronous Machine Dynamics 165
8.1 Synchronous Machine Modeling and Machine Parameters 165
8.2 Some Basic Examples 167
8.2.1 No-Load Transmission Line Charging 167
8.2.2 Power Flow Calculation 169
8.2.3 Sudden Short-Circuiting 172
8.3 Transient Stability Analysis Applying the Synchronous Machine Model 176
8.3.1 Classic Analysis (Equal-Area Method) and Time Domain Analysis (EMTP) 176
8.3.2 Detailed Transients by Time Domain Analysis: ATP-EMTP 180
8.3.3 Field Excitation Control 183
8.3.4 Back-Swing Phenomenon 186
Appendix 8.A: Short-Circuit Phenomena Observation in d-q Domain Coordinate 190
Appendix 8.B: Starting as an Induction Motor 193
Appendix 8.C: Modeling by the No. 19 Universal Machine 195
Appendix 8.D: Example of ATPDraw Picture File: Draw8-111.acp (Figure D8.1). 197
References 198
9 Induction Machine, Doubly Fed Machine, Permanent Magnet Machine 199
9.1 Induction Machine (Cage Rotor Type) 199
9.1.1 Machine Data for EMTP Calculation 200
9.1.2 Zero Starting 201
9.1.3 Mechanical Torque Load Application 204
9.1.4 Multimachines 206
9.1.5 Motor Terminal Voltage Change 208
9.1.6 Driving by Variable Voltage and Frequency Source (VVVF) 209
9.2 Doubly Fed Machine 212
9.2.1 Operation Principle 212
9.2.2 Steady-State Calculation 213
9.2.3 Flywheel Generator Operation 213
9.3 Permanent Magnet Machine 215
9.3.1 Zero Starting (Starting by Direct AC Voltage Source Connection) 217
9.3.2 Calculation of Transient Phenomena 217
Appendix 9.A: Doubly Fed Machine Vector Diagrams 218
Appendix 9.B: Example of ATPDraw Picture 219
10 Machine Drive Applications 221
10.1 Small-Scale System Composed of a Synchronous Generator and Induction Motor 221
10.1.1 Initialization 221
10.1.2 Induction Motor Starting 223
10.1.3 Application of AVR 225
10.1.4 Inverter-Controlled VVVF Starting 226
10.2 Cycloconverter 233
10.3 Cycloconverter-Driven Synchronous Machine 237
10.3.1 Application of Sudden Mechanical Load 237
10.3.2 Quick Starting of a Cycloconverter-Driven Synchronous Motor 242
10.3.3 Comparison with the Inverter-Driven System 245
10.4 Flywheel Generator: Doubly Fed Machine Application for Transient Stability Enhancement 248
10.4.1 Initialization 249
10.4.2 Flywheel Activity in Transient Stability Enhancement 254
10.4.3 Active/Reactive Power Effect 254
10.4.4 Discussion 258
Appendix 10.A: Example of ATPDraw Picture 260
Reference 266
Index 267
1
Fundamentals of EMTP
The Electromagnetic Transients Program (EMTP) is a powerful analysis tool for circuit phenomena in power systems. Both steady state voltage and current distribution in the fundamental frequency and surge phenomena in a high-frequency region can be solved using EMTP. Selection of suitable models and appropriate parameters is required for getting correct results. Many comparisons of calculation results and actual recorded data are carried out, and accuracy of EMTP is discussed. Through such applications, EMTP is used widely in the world. EMTP can treat not only main equipment but also control functions. ATP-EMTP is a program that came from EMTP. After ATPDraw (which provides an easy, simple, and powerful graphical user interface) was developed, ATP-EMTP was able to expand its user ability.
1.1 Function and Composition of EMTP
Built-in models in EMTP are listed in Tables 1.1 and 1.2. Table 1.1 shows a main circuit model and Table 1.2 shows a control model. There are two ways to simulate control; one is TACS (Transient Analysis of Control Systems) and the other is MODELS. MODELS is a flexible modeling language and permits more complex calculations than TACS. All statements in MODELS must be written by the user. MODELS is not covered in this book, but TACS is explained for representing control.
Table 1.1 Main circuit model.
Main Circuit Equipment | Built-in Model |
Lumped parameter RLC | Series RLC branch |
Transmission line, cable | Mutually coupled RLC element, Multiphase PI equivalent (Type 1, 2, 3) |
Distributed parameter line with lumped R (Type-1, -2, -3) |
Frequency dependent distributed parameter line, JMARTI (Type-1, -2, -3) |
Frequency dependent distributed parameter line, SEMLYEN (Type-1) |
Transformer | Single-phase saturable transformer |
Three-phase saturable transformer |
Three-phase three-leg core-type transformer |
Mutually coupled RL element (Type 51, 52) |
Nonlinear element | Multiphase time varying resistance (Type 91) |
True nonlinear inductance (Type 93) |
Pseudo nonlinear hysteretic inductor (Type 96) |
Staircase time varying resistance (Type 97) |
Pseudo nonlinear inductor (Type 98) |
Pseudo nonlinear resistance (Type 99) |
TACS controlled resistance for arc model (Type 91) |
Arrester | Multiphase time-varying resistance (Type 91) |
Exponential ZnO (Type 92) |
Multiphase piecewise linear resistance with flashover (Type 92) |
Switch | Time-controlled switch |
Voltage-controlled switch |
Statistical switch |
Measuring switch |
TACS controlled switch | Diode, thyristor (Type 11) |
Purely TACS-controlled switch (Type 13) |
Voltage source, current source | Empirical data source (Type 1–9) |
Step function (Type 11) |
Ramp function (Type 12) |
Two slopes ramp function (Type 13) |
Sinusoidal function (Type 14) |
CIGRE surge model (Type 15) |
Simplified HVDC converter (Type 16) |
Ungrounded voltage source (Type 18) |
TACS controlled source (Type 60) |
Generator | Three-phase synchronous machine (Type 58, 59) |
Universal machine module (Type 19) |
Rotating machine | Universal machine module (Type 19) |
Control | TACS |
MODELS |
Table 1.2 Control model.
Control Element | Built-in Function in TACS |
Transfer function | , |
Devices | Frequency sensor (50) |
Relay operated switch (51) |
Level triggered switch (52) |
Transport delay (53) |
Pulse transport delay (54) |
Digitizer (55) |
Point-by-point nonlinear (56) |
Time sequence switch (57) |
Controlled integrator (58) |
Simple derivative (59) |
Input-If selector (60) |
Signal selector (61) |
Sample and track (62) |
Instantaneous min/max (63) |
Min/max tracking (64) |
Accumulator and counter (65) |
RMS meter (66) |
Algebraic and logical expression | +, −, *, /, AND, OR, NOT, EQ, GE, SIN, COS, TAN, ASIN, ACOS, ATAN, LOG, LOG10, EXP, SQRT, ABS |
Free format FORTRAN |
Signal source | DC level (Type 11) |
Sinusoidal signal (Type 14) |
Pulse (Type 23) |
Ramp (Type 24) |
Input signal from main circuit | Node voltage (Type 90) |
Switch current (Type 91) |
Synchronous machine internal signal (Type 92) |
Switch state (Type 93) |
Output signal to main circuit | On/off signal for TACS-controlled switch |
Signal for TACS-controlled source |
Torque and field voltage signals for synchronous machine |
1.1.1 Lumped Parameter RLC
The Series RLC Branch model is prepared for representing power system circuits. Load, shunt reactor, shunt capacitor, filter, and other lumped parameter components are represented using this model.
1.1.2 Transmission Line
The multiphase PI-equivalent circuit model, Type 1, 2, and 3, is used as a simple line model. It has mutual coupling inductors and is applicable to a transposed or nontransposed three-phase transmission line.
The distributed parameter line model with lumped resistance, Type-1, -2, and -3, consists of a lossless distributed parameter line model and constant resistances. The resistance is inserted into the lossless line in the mode. Normally the resistance corresponding to the fundamental frequency is used, then this model is applicable to phenomena from the fundamental frequency to the harmonic frequency, in the 1–2 kHz region.
The frequency-dependent distributed parameter line model developed by J. Marti, Semlyen, takes into account line losses at high frequency, even in an untransposed line. It enables the production of detailed and precise simulation for surge analysis. The required data for use of the model can be obtained using support routine Line Constants or Cable Constants, explained later. Height of transmission line tower, conductor configuration, and necessary data are inputted to the support routine, and the input data for EMTP are calculated by the support routine. Both cables and overhead lines are treated by these support routines.
1.1.3 Transformer
A single-phase saturable transformer model is a basic component that permits a multiwinding configuration. The two- or three-winding model is used in many study cases. A pseudo nonlinear inductor is included in this model for saturation characteristics. Input data are resistance and inductance of each winding. A three-phase saturable transformer model also is prepared. The three-phase three-leg transformer is applied for a core type transformer that has a path for air gap flux generated by a zero sequence component. When a hysteresis characteristic is desired, the pseudo nonlinear hysteretic inductor, Type 96, should be used instead of the incorporated pseudo nonlinear inductor. In such a case, the Type 96 branch will be connected outside of the transformer model. The mutually coupled RL element is used for representing a multiwinding transformer; however, self and mutual inductances of all windings are required for input data. This is used for transition voltage analysis in the transformer, which requires a multiwinding model.
1.1.4 Nonlinear...
Erscheint lt. Verlag | 29.2.2016 |
---|---|
Sprache | englisch |
Themenwelt | Naturwissenschaften ► Physik / Astronomie |
Technik ► Elektrotechnik / Energietechnik | |
Schlagworte | Circuit Theory & Design • Electrical & Electronics Engineering • electric power systems • Electro- magnetic transient phenomena • Elektrische Energietechnik • Elektrotechnik u. Elektronik • Energie • Energietechnik • Energy • Failure in electric power supply • Power Electronics • Power supply network • Power Technology & Power Engineering • Schaltkreise - Theorie u. Entwurf • Schaltkreistechnik • Smart Grid • Switching equipment • Ultra high voltage transmission |
ISBN-10 | 1-118-73747-4 / 1118737474 |
ISBN-13 | 978-1-118-73747-7 / 9781118737477 |
Informationen gemäß Produktsicherheitsverordnung (GPSR) | |
Haben Sie eine Frage zum Produkt? |

Größe: 37,8 MB
Kopierschutz: Adobe-DRM
Adobe-DRM ist ein Kopierschutz, der das eBook vor Mißbrauch schützen soll. Dabei wird das eBook bereits beim Download auf Ihre persönliche Adobe-ID autorisiert. Lesen können Sie das eBook dann nur auf den Geräten, welche ebenfalls auf Ihre Adobe-ID registriert sind.
Details zum Adobe-DRM
Dateiformat: PDF (Portable Document Format)
Mit einem festen Seitenlayout eignet sich die PDF besonders für Fachbücher mit Spalten, Tabellen und Abbildungen. Eine PDF kann auf fast allen Geräten angezeigt werden, ist aber für kleine Displays (Smartphone, eReader) nur eingeschränkt geeignet.
Systemvoraussetzungen:
PC/Mac: Mit einem PC oder Mac können Sie dieses eBook lesen. Sie benötigen eine
eReader: Dieses eBook kann mit (fast) allen eBook-Readern gelesen werden. Mit dem amazon-Kindle ist es aber nicht kompatibel.
Smartphone/Tablet: Egal ob Apple oder Android, dieses eBook können Sie lesen. Sie benötigen eine
Geräteliste und zusätzliche Hinweise
Zusätzliches Feature: Online Lesen
Dieses eBook können Sie zusätzlich zum Download auch online im Webbrowser lesen.
Buying eBooks from abroad
For tax law reasons we can sell eBooks just within Germany and Switzerland. Regrettably we cannot fulfill eBook-orders from other countries.

Größe: 75,0 MB
Kopierschutz: Adobe-DRM
Adobe-DRM ist ein Kopierschutz, der das eBook vor Mißbrauch schützen soll. Dabei wird das eBook bereits beim Download auf Ihre persönliche Adobe-ID autorisiert. Lesen können Sie das eBook dann nur auf den Geräten, welche ebenfalls auf Ihre Adobe-ID registriert sind.
Details zum Adobe-DRM
Dateiformat: EPUB (Electronic Publication)
EPUB ist ein offener Standard für eBooks und eignet sich besonders zur Darstellung von Belletristik und Sachbüchern. Der Fließtext wird dynamisch an die Display- und Schriftgröße angepasst. Auch für mobile Lesegeräte ist EPUB daher gut geeignet.
Systemvoraussetzungen:
PC/Mac: Mit einem PC oder Mac können Sie dieses eBook lesen. Sie benötigen eine
eReader: Dieses eBook kann mit (fast) allen eBook-Readern gelesen werden. Mit dem amazon-Kindle ist es aber nicht kompatibel.
Smartphone/Tablet: Egal ob Apple oder Android, dieses eBook können Sie lesen. Sie benötigen eine
Geräteliste und zusätzliche Hinweise
Zusätzliches Feature: Online Lesen
Dieses eBook können Sie zusätzlich zum Download auch online im Webbrowser lesen.
Buying eBooks from abroad
For tax law reasons we can sell eBooks just within Germany and Switzerland. Regrettably we cannot fulfill eBook-orders from other countries.
aus dem Bereich