Omnidirectional Inductive Powering for Biomedical Implants investigates the feasibility of inductive powering for capsule endoscopy and freely moving systems in general. The main challenge is the random position and orientation of the power receiving system with respect to the emitting magnetic field. Where classic inductive powering assumes a predictable or fixed alignment of the respective coils, the remote system is now free to adopt just any orientation while still maintaining full power capabilities. Before elaborating on different approaches towards omnidirectional powering, the design and optimisation of a general inductive power link is discussed in all its aspects. Special attention is paid to the interaction of the inductive power link with the patient's body. Putting theory into practice, the implementation of an inductive power link for a capsule endoscope is included in a separate chapter.
Omnidirectional Inductive Powering for Biomedical Implants investigates the feasibility of inductive powering for capsule endoscopy and freely moving systems in general. The main challenge is the random position and orientation of the power receiving system with respect to the emitting magnetic field. Where classic inductive powering assumes a predictable or fixed alignment of the respective coils, the remote system is now free to adopt just any orientation while still maintaining full power capabilities. Before elaborating on different approaches towards omnidirectional powering, the design and optimisation of a general inductive power link is discussed in all its aspects. Special attention is paid to the interaction of the inductive power link with the patient's body. Putting theory into practice, the implementation of an inductive power link for a capsule endoscope is included in a separate chapter.

Abstract. List of Abbreviations and Symbols. 1 Introduction. 1.1 Wireless Power Transmission. 1.2 Types of Wireless Power Transmission. 1.3 A Biomedical Perspective. 1.4 Inductive Links. 1.5 Conclusions. 1.6 What to Expect. 2 Magnetic Induction. 2.1 Maxwell’s Equations. 2.2 Conductive Wire. 2.3 Inductance. 2.4 Inductor Models. 2.5 Finite Element Modelling. 2.6 Conclusions. 3 Inductive Link Design. 3.1 Link Equations. 3.2 Loose-coupling Approximation. 3.3 Tertiary Circuits. 3.4 Link Optimisation. 3.5 Misconceptions about k and Q. 3.6 Conclusions. 4 Power Converters and Voltage Regulators. 4.1 Rectifiers. 4.2 Inverters. 4.3 Voltage Regulators. 4.4 Conclusions. 5 Omnidirectional Coupling. 5.1 Problem Definition. 5.2 Multiple Primary Coils. 5.3 Multiple Secondary Coils. 5.4 Conclusions. 6 Biological Tissue Interaction. 6.1 Electromagnetic Fields in Biological Tissue. 6.2 Health Effects of Electromagnetic Fields. 6.3 Exposure Limits and Regulations. 6.4 Examples from Biomedical Engineering Practice. 6.5 Conclusions. 7 An Inductive Power Link for a Capsule Endoscope. 7.1 Wireless Endoscopy. 7.2 Design: Choices and Motivation. 7.3 Fabrication. 7.4 Measurement. 7.5 Biological Tissue Interaction. 7.6 Conclusions. 8 A Class E Driver for Deformable Coils. 8.1 Class E ZVS Inverter with Transductor. 8.2 Control Loop. 8.3 Measurement Results. 8.4 Conclusions. 9 Conclusions. 9.1 Comprehensive Summary. 9.2 Main Contributions and Achievements. 9.3 Further Research. Appendix: Coil Measurements. A.1 Single Coil Characterisation. A.2 Coupling Characterisation. References. Index.

Erscheint lt. Verlag 14.10.2008
Reihe/Serie Analog Circuits and Signal Processing
Zusatzinfo XVI, 222 p.
Verlagsort Dordrecht
Sprache englisch
Themenwelt Medizinische Fachgebiete Chirurgie Ästhetische und Plastische Chirurgie
Medizin / Pharmazie Physiotherapie / Ergotherapie Orthopädie
Naturwissenschaften Biologie
Technik Elektrotechnik / Energietechnik
Technik Medizintechnik
Schlagworte biomedical engineering • capsule endoscope • inductive link • omnidirectional • tissue • wireless powering
ISBN-10 1-4020-9075-7 / 1402090757
ISBN-13 978-1-4020-9075-2 / 9781402090752
Haben Sie eine Frage zum Produkt?
Wie bewerten Sie den Artikel?
Bitte geben Sie Ihre Bewertung ein:
Bitte geben Sie Daten ein:
PDFPDF (Wasserzeichen)
Größe: 4,1 MB

DRM: Digitales Wasserzeichen
Dieses eBook enthält ein digitales Wasser­zeichen und ist damit für Sie persona­lisiert. Bei einer missbräuch­lichen Weiter­gabe des eBooks an Dritte ist eine Rück­ver­folgung an die Quelle möglich.

Dateiformat: PDF (Portable Document Format)
Mit einem festen Seiten­layout eignet sich die PDF besonders für Fach­bücher mit Spalten, Tabellen und Abbild­ungen. Eine PDF kann auf fast allen Geräten ange­zeigt werden, ist aber für kleine Displays (Smart­phone, eReader) nur einge­schränkt geeignet.

Systemvoraussetzungen:
PC/Mac: Mit einem PC oder Mac können Sie dieses eBook lesen. Sie benötigen dafür einen PDF-Viewer - z.B. den Adobe Reader oder Adobe Digital Editions.
eReader: Dieses eBook kann mit (fast) allen eBook-Readern gelesen werden. Mit dem amazon-Kindle ist es aber nicht kompatibel.
Smartphone/Tablet: Egal ob Apple oder Android, dieses eBook können Sie lesen. Sie benötigen dafür einen PDF-Viewer - z.B. die kostenlose Adobe Digital Editions-App.

Zusätzliches Feature: Online Lesen
Dieses eBook können Sie zusätzlich zum Download auch online im Webbrowser lesen.

Buying eBooks from abroad
For tax law reasons we can sell eBooks just within Germany and Switzerland. Regrettably we cannot fulfill eBook-orders from other countries.

Mehr entdecken
aus dem Bereich
Anatomy, Technique, & Clinical Applications

von Phillip N. Blondeel; Geoffrey G. Hallock; Steven F. Morris …

eBook Download (2024)
Thieme Publishers New York (Verlag)
544,99